MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 8.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 4.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.620 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | FTF 15 |
AKAE | MAXIMUM OPERATING ALTITUDE RATING | 10000.0 FEET |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 103.5 AC VOLTS MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 126.5 AC VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 207.0 AC VOLTS MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 253.0 AC VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 11.4 DC VOLTS MINIMUM 3RD POWER OUTPUT AND 12.6 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 128.2 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 141.7 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 4.7 DC VOLTS MINIMUM 4TH POWER OUTPUT AND 5.2 DC VOLTS MAXIMUM 4TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 52.2 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 57.7 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 500.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -25.0/71.0 DEG CELSIUS |
CWGH | OUTPUT CURRENT RATING | 100.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 150.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 4.0 DC AMPERES NOMINAL 4TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 500.0 DC MILLIAMPERES NOMINAL 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 8 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP SINGLE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 3 SINGLE OPERATING POWER RQMT |