Thank you for your interest in Eaton Corporation part number JA1S-E3-AA-04-W-A-10-03, a Circuit Breaker item that we offer here on Aerospace Materials Supply. This product is listed with the NSN 5925-01-351-5541, and you can obtain customized procurement solutions on this component from our team members by completing and submitting the form below. For our specialists to best deliver quotes that accommodate your specifications, please be sure we are presented with essential details like your target price, desired quantity, and anticipated fulfillment timeline. Once we have the opportunity to receive and review your submission, we will strive to provide a tailored response for your consideration within 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
Besides part number JA1S-E3-AA-04-W-A-10-03, you may browse our platform further for similar components produced by Eaton Corporation under the CAGECode 74193, as well as additional products that are categorized under FSC 5925 Circuit Breakers. If you have any questions regarding our services or the NSN 5925-01-351-5541 items that we sell, you may always give us a call or email, as we would be delighted to assist you in any way that we can. Otherwise, we encourage you to request a quote for part number JA1S-E3-AA-04-W-A-10-03 at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-351-5541 Item PartTypeName: CIRCUIT BREAKER | 5925 | 013515541 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
JA1S-E3-AA-04-W-A-10-03 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.560 INCHES NOMINAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CWJK | CASE MATERIAL | PLASTIC |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB,SOLDER LUG |
ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.930 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC AND 10.0 AMPERES DC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC AND 65.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC AND 1000.0 DC ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.200 MINIMUM AT 200 PCT AND 2.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
FREQ | FREQUENCY IN HERTZ | 50.0 OR 60.0 ALL LOCATIONS |
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAT | BODY WIDTH | 0.750 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.660 INCHES NOMINAL |
AJEC | BOSS HEIGHT | 0.130 INCHES NOMINAL |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
THSD | THREAD SERIES DESIGNATOR | UNC |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |