Thank you for your interest in Lockheed Martin Corporation part number C20495-1, a Powersupply item that we offer here on Aerospace Materials Supply. This product is listed with the NSN 6130-01-398-9105, and you can obtain customized procurement solutions on this component from our team members by completing and submitting the form below. For our specialists to best deliver quotes that accommodate your specifications, please be sure we are presented with essential details like your target price, desired quantity, and anticipated fulfillment timeline. Once we have the opportunity to receive and review your submission, we will strive to provide a tailored response for your consideration within 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
Besides part number C20495-1, you may browse our platform further for similar components produced by Lockheed Martin Corporation under the CAGECode 81755, as well as additional products that are categorized under FSC 6130 Converters Electrical Non Rotating. If you have any questions regarding our services or the NSN 6130-01-398-9105 items that we sell, you may always give us a call or email, as we would be delighted to assist you in any way that we can. Otherwise, we encourage you to request a quote for part number C20495-1 at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-398-9105 Item PartTypeName: POWER SUPPLY | 6130 | 013989105 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
ALPHA 3807-01GD | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ANPM | INPUT PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 220.0 AC POUNDS PER HOUR DRY 3RD ALTERNATE OPERATING POWER RQMT AND 230.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 3RD ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | CONNECTOR,RECEPTACLE SINGLE POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 3RD ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 2ND ALTERNATE OPERATING POWER RQMT |
ABKW | OVERALL HEIGHT | 5.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 13.110 INCHES NOMINAL |
ANPM | INPUT PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 120.0 AC POUNDS PER HOUR DRY 2ND ALTERNATE OPERATING POWER RQMT AND 130.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND ALTERNATE OPERATING POWER RQMT |
CWKG | VENTILATION DESIGN TYPE | CONVECTION |
ABHP | OVERALL LENGTH | 19.000 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | F-15 |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 3RD ALTERNATE OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 4TH ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 230.0 AC POUNDS PER HOUR DRY 4TH ALTERNATE OPERATING POWER RQMT AND 250.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 4TH ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 DC KILOVOLTS MINIMUM SINGLE POWER OUTPUT AND 30.0 DC KILOVOLTS MAXIMUM SINGLE POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 3RD ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 48.0 HERTZ MINIMUM 4TH ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 4TH ALTERNATE OPERATING POWER RQMT |
CWGH | OUTPUT CURRENT RATING | 0.0 DC MILLIAMPERES MINIMUM SINGLE POWER OUTPUT AND 1.5 DC MILLIAMPERES MAXIMUM SINGLE POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 SINGLE POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
CWHM | INPUT CURRENT RATING | 70.0 AC AMPERES NOMINAL 4TH ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 1ST ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 3RD ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 4TH ALTERNATE OPERATING POWER RQMT |
FEAT | SPECIAL FEATURES | OUTPUT VOLTAGE ANALOG METER,CONTROL SELECTOR SWITCH,VOLTAGE AND CURRENT ADJUSTABLE,LOCAL CONTROL POTENTIOMETER,ELECTROSTATIC SENSITIVE DEVICE |
APNX | INPUT VOLTAGE RATING | 90.0 AC POUNDS PER HOUR DRY 1ST ALTERNATE OPERATING POWER RQMT AND 110.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST ALTERNATE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/50.0 DEG CELSIUS |