Thank you for your interest in Sensata Technologies Inc part number APL111125978-102, a Circuitbreaker item that we offer here on Aerospace Materials Supply. This product is listed with the NSN 5925-01-407-2542, and you can obtain customized procurement solutions on this component from our team members by completing and submitting the form below. For our specialists to best deliver quotes that accommodate your specifications, please be sure we are presented with essential details like your target price, desired quantity, and anticipated fulfillment timeline. Once we have the opportunity to receive and review your submission, we will strive to provide a tailored response for your consideration within 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
Besides part number APL111125978-102, you may browse our platform further for similar components produced by Sensata Technologies Inc under the CAGECode 81541, as well as additional products that are categorized under FSC 5925 Circuit Breakers. If you have any questions regarding our services or the NSN 5925-01-407-2542 items that we sell, you may always give us a call or email, as we would be delighted to assist you in any way that we can. Otherwise, we encourage you to request a quote for part number APL111125978-102 at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-407-2542 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014072542 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
H505A001-102 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
TTQY | Terminal Type And Quantity | 8 COMPRESSION |
MRC | Decoded Requirement | Clear Text Reply |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.060 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 40.0 AMPERES AC SECOND LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 40.0 AMPERES AC THIRD LOCATION |
AJEC | Boss Height | 0.150 INCHES NOMINAL |
AKPX | Pole Quantity | 4 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC THIRD LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC FIRST LOCATION |
FREQ | Frequency In Hertz | 60.0 FIRST LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC THIRD LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC SECOND LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 DC FIRST LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2000.0 DC FOURTH LOCATION |
FREQ | Frequency In Hertz | 60.0 SECOND LOCATION |
FREQ | Frequency In Hertz | 60.0 THIRD LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
THSD | Thread Series Designator | UNC |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
AXHR | Mounting Facility Type And Quantity | 8 THREADED HOLE |
ADAT | Body Width | 3.015 INCHES MAXIMUM |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, THREE, AND FOUR LINKED |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.645 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 2.530 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 40.0 AMPERES AC FIRST LOCATION |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC SECOND LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 3.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 4 TOGGLE |