Thank you for your interest in Spd Electrical Systems Inc part number ETN-1024, a Circuitbreaker item that we offer here on Aerospace Materials Supply. This product is listed with the NSN 5925-01-418-9844, and you can obtain customized procurement solutions on this component from our team members by completing and submitting the form below. For our specialists to best deliver quotes that accommodate your specifications, please be sure we are presented with essential details like your target price, desired quantity, and anticipated fulfillment timeline. Once we have the opportunity to receive and review your submission, we will strive to provide a tailored response for your consideration within 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
Besides part number ETN-1024, you may browse our platform further for similar components produced by Spd Electrical Systems Inc under the CAGECode 30086, as well as additional products that are categorized under FSC 5925 Circuit Breakers. If you have any questions regarding our services or the NSN 5925-01-418-9844 items that we sell, you may always give us a call or email, as we would be delighted to assist you in any way that we can. Otherwise, we encourage you to request a quote for part number ETN-1024 at your earliest convenience.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-418-9844 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014189844 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
ETN-1024 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
AKPX | Pole Quantity | 3 |
CRCF | Trip Release Ambient Temp Rating | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPLM | Maximum Continuous Load Current Rating Per Pole | 25.0 AMPERES DC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 DC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 2500.0 DC ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |