Thank you for your interest in Vindicator Corp part number UPS-1210, a Power Supply item that we offer here on Aerospace Materials Supply. This product is listed with the NSN 6130-01-373-5184, and you can obtain customized procurement solutions on this component from our team members by completing and submitting the form below. For our specialists to best deliver quotes that accommodate your specifications, please be sure we are presented with essential details like your target price, desired quantity, and anticipated fulfillment timeline. Once we have the opportunity to receive and review your submission, we will strive to provide a tailored response for your consideration within 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
Besides part number UPS-1210, you may browse our platform further for similar components produced by Vindicator Corp under the CAGECode 58304, as well as additional products that are categorized under FSC 6130 Converters Electrical Non Rotating. If you have any questions regarding our services or the NSN 6130-01-373-5184 items that we sell, you may always give us a call or email, as we would be delighted to assist you in any way that we can. Otherwise, we encourage you to request a quote for part number UPS-1210 at your earliest convenience.
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 11.200 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 9.000 INCHES NOMINAL |
AEXR | BATTERY QUANTITY | 1 |
AGAV | END ITEM IDENTIFICATION | INTRUSION DETECT ALARM SYSTEM |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMTSINGLE 2ND ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 120.0 AC POUNDS PER HOUR WET 1ST ALTERNATE OPERATING POWER RQMT220.0 AC POUNDS PER HOUR WET 2ND ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT47.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
CWGH | OUTPUT CURRENT RATING | 1.0 DC AMPERES NOMINAL SINGLE POWER OUTPUT |
CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 2.5 MILLIVOLTS PEAK SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
CWHY | BATTERY FEATURE AND TYPE | RECHARGEABLE NICKEL CADMIUM |
CWJF | BATTERY LOCATION | INTERNAL |
CWWB | BATTERY RECOVERY TIME | 12.0 |
CXMN | BATTERY SWITCHING TIME | INSTANTANEOUS |
CXMX | BATTERY POWER SUPPLY EMERGENCY OPERATING TIME | 4.0 |
FEAT | SPECIAL FEATURES | USES BATTERY P/N BAT-1260 |